Related in stock products

Agilent 86130A Bit Analyzer 3.6 Gb/s

The 86130A BitAlyzer is a 3.6 Gb/s general-purpose bit error ratio tester designed for high-speed digital components and systems.

Read more
5 1
,
5/ 5
Out-of-Stock
Condition
Used
Reference:
86130A
Brand:
Description

Agilent 86130A Bit Error Performance Analyzer

Specifications

Pattern Generator Parameters
Operating Frequency
50 MHz to 3.0 GHz with internal clock source
Internal Clock Source
Frequency Range
50 MHz to 3.0 GHz
Frequency Accuracy
±20 ppm

Pattern Generator
Input/Output Specifications

Data and Data Outputs
Data and Data outputs are independently settable
Format: NRZ
Polarity: Normal or Inverted
Amplitude: 0.5 to 2 V in 10 mV steps
Offset: 10mV resolution.
Data Outputs On/Off: ‘Off’ goes to high impedance state
Supported Terminations:
0 V (LVTTL, SCFL, etc.), –2 V (ECL), +1.3 V (3.3 V PECL),
AC-coupled
Jitter (pk-pk): <20 ps, <12 ps typical (w/internal source)
Transition Time (10–90%): <42 ps, <30 ps typical (25C)
Variable Crossover: Supported
Clock/ Data Delay Range: 0–1 bit period or 10 ns,
whichever is less. 1 ps resolution.
Interface: DC-coupled
50½ reverse terminated,
APC-3.5 connector

Clock and Clock Outputs
Clock and Clock outputs are independently settable
Amplitude: 0.5 to 2 V in 10 mV steps
Clock Outputs On/Off: ‘Off’ goes to high impedance state
Supported Terminations:
0 V (LVTTL, SCFL, etc.), –2 V (ECL), +1.3 V (3.3 V PECL),
AC-coupled
Transition Time (10–90%): <42 ps, <35 ps typical (25C, 3 GHz)
Interface: DC-coupled 50½ reverse terminated, APC-3.5 connector

Error Detector Parameters
Operating Frequency 50 MHz to 3.6 GHz.

Error Detector
Input/Output Specifications

Data Input
Polarity: Normal or Inverted
Input Amplitude: 0.1 to 2 V (typical)
Threshold Range: +3 to –3 V
Threshold Resolution: 0.5 mV
Terminations: Via 50½ to –2 V, 0 V, +1.3 V
Data Input Delay Range: 0–1 bit period, or 10 ns
whichever is less. 1 ps resolution
Interface: DC-coupled 50½, APC-3.5 female connector

Clock Input
Clock Input functions—switchable termination voltages,
input frequency measurement, clock invert.
Bit Rate: 50 MHz to 3.6 GHz
Data Sampling Clock Edge: Selectable Rising or Falling
Input Amplitude: 0.2 to 2 V (typical)
Terminations: Via 50½ to –2 V, 0 V, +1.3 V
Interface: DC-coupled 50½, APC-3.5 female

Environmental
Warm-up time 30 minutes
Operating Temperature Range to specification 10 to 45°C
Humidity 15 to 95% at 45°C non-condensing
Electrical
Supply Voltage Parameters 90 V–250V AC, 50–60Hz
Power Consumption <300W