You may also like

HP 83481A Option 040 Optical/Electrical DCA Module with 155/622 Mb/s SONET/SDH Filter

The HP 83481A Option 040 is an optical/electrical plug-in module for compatible HP 83480A and 54750A digital communications analyzer mainframes. It combines a calibrated 2.85 GHz optical channel with a switchable 155/622 Mb/s SONET/SDH reference-receiver filter, a selectable 12.4 GHz or 20 GHz electrical channel, and a 2.5 GHz trigger input. Calibrated operation at 1310 nm and 1550 nm, average optical power monitoring, 9/125 µm single-mode fiber compatibility, and high-speed electrical measurements support optical transmitter testing, waveform analysis, SONET/SDH compliance work, and telecom component characterization.

Download the HP/Agilent 83481A Specification Sheet (PDF)

Read moreShow less

Request Pricing

5 1
,
5/ 5
Yes, we have more than 5 in stock
Condition
Used
Reference:
83481Aopt040
Brand:
Description

HP 83481A Option 040 Optical/Electrical DCA Module

The HP 83481A Option 040 is a combined optical and electrical plug-in module designed for compatible HP 83480A and HP 54750A digital communications analyzer mainframes. It provides a calibrated optical measurement channel, a high-speed electrical measurement channel, and a dedicated trigger input in one modular instrument.

Option 040 equips the optical channel with a switchable 155/622 Mb/s SONET/SDH reference-receiver filter. This configuration supports transmitter compliance measurements at STM-1/OC-3 and STM-4/OC-12 data rates while retaining an unfiltered optical bandwidth of 2.85 GHz for general waveform characterization.

The electrical channel offers user-selectable bandwidths of 12.4 GHz and 20 GHz. The 12.4 GHz setting provides lower measurement noise, while the 20 GHz setting preserves faster transitions and additional detail in high-speed electrical waveforms. A separate 2.5 GHz trigger input supports stable acquisition from compatible clock or data signals.

Features and Benefits of the HP 83481A Option 040

The HP 83481A Option 040 provides optical and electrical measurement capability for engineers working with high-speed fiber optic transmitters, receivers, modules, and communication systems.

  • Integrated optical and electrical channels: Measures optical power waveforms and high-speed electrical signals from one plug-in module.
  • Option 040 SONET/SDH filtering: Provides switchable reference-receiver filtering for 155 Mb/s and 622 Mb/s optical communication signals.
  • Calibrated optical receiver: Displays optical waveforms in calibrated power units and includes average optical power monitoring.
  • 2.85 GHz optical bandwidth: Supports high-fidelity unfiltered characterization of compatible optical signals.
  • Selectable electrical bandwidth: Allows the electrical channel to operate at 12.4 GHz or 20 GHz.
  • Fast electrical transition response: Provides calculated transition times of 28.2 ps at 12.4 GHz and 17.5 ps at 20 GHz.
  • Calibrated telecom wavelengths: Factory calibration is provided at 1310 nm and 1550 nm.
  • Broad user-calibration range: Supports user wavelength calibration across the optical receiver’s 1000 nm to 1600 nm operating range.
  • Average optical power monitor: Measures average power over a specified range from -30 dBm to -4 dBm.
  • 2.5 GHz trigger channel: Provides a separate 50-ohm trigger input for compatible electrical timing signals.
  • Single-mode fiber input: Uses a universal optical interface for compatible 9/125 µm single-mode fiber adapters.
  • Probe and auxiliary power: Includes one probe-power connector and one auxiliary-power connector.

Option 040 SONET/SDH Reference Receiver

Option 040 provides switchable optical reference-receiver filters for 155 Mb/s and 622 Mb/s data rates. These correspond to STM-1/OC-3 and STM-4/OC-12 optical communication applications.

The filtered optical response is designed to conform to the applicable reference-receiver requirements of ITU-T G.957 and GR-253-CORE. Reference-receiver filtering allows an optical transmitter waveform to be evaluated with the standardized bandwidth and frequency response used for SONET and SDH compliance testing.

The filter can be inserted when performing standardized transmitter measurements and removed when an unfiltered representation of the optical waveform is needed. This allows the same module to support both compliance-oriented measurements and general waveform troubleshooting.

Integrated Calibrated Optical Channel

The HP 83481A incorporates a calibrated optical receiver directly into the plug-in module. The integrated receiver reduces the need for an external optical-to-electrical converter and the additional cables, connectors, and impedance transitions associated with an external measurement arrangement.

The optical channel displays received signals in optical power units rather than only presenting the output voltage from an external detector. It can also measure the average optical power of the connected signal.

The receiver is factory calibrated at 1310 nm and 1550 nm. A user wavelength calibration can be performed with a suitable optical source and power meter for measurements at other wavelengths within the supported 1000 nm to 1600 nm range.

Optical Bandwidth and Transition Response

The unfiltered optical channel has a specified bandwidth from DC to 2.85 GHz and a characteristic bandwidth extending to 3.0 GHz. This bandwidth supports waveform characterization of compatible optical transmitters and communication signals.

The optical transition time is specified at no more than 245 ps in unfiltered mode. Filtered response is determined by the selected 155 Mb/s or 622 Mb/s SONET/SDH reference-receiver mode.

Actual displayed rise time depends on the incoming optical signal, connected mainframe, selected filter, calibration condition, waveform amplitude, trigger quality, and acquisition settings.

Optical Input Power and Average Power Monitoring

The maximum specified peak optical input is 0.6 mW, or -2.2 dBm, for a continuous-wave signal. The maximum specified peak input for a modulated optical signal is 0.4 mW, or -4 dBm. Exceeding these levels can cause waveform distortion.

The average optical power monitor has a specified operating range from -30 dBm to -4 dBm, equivalent to approximately 1 µW to 400 µW. The factory-calibrated average power accuracy is ±5% of reading, plus 100 nW and connector uncertainty, from 20 °C to 30 °C.

The maximum safe optical input is 10 mW peak. This safety limit is higher than the maximum specified measurement level and should not be interpreted as an undistorted operating range.

12.4 GHz and 20 GHz Electrical Channel

The electrical measurement channel provides selectable bandwidths from DC to 12.4 GHz or DC to 20 GHz. The lower bandwidth mode reduces displayed noise, while the full 20 GHz mode provides improved fidelity for faster electrical transitions.

At 12.4 GHz, the calculated 10% to 90% transition time is 28.2 ps or less. At 20 GHz, the calculated transition time is 17.5 ps or less.

Maximum RMS noise is 0.5 mV in the 12.4 GHz mode and 1 mV in the 20 GHz mode. Typical RMS noise values are 0.25 mV and 0.5 mV respectively.

Electrical Input and Scaling

The electrical channel has a nominal impedance of 50 ohms and uses a 3.5 mm male connector. The vertical scale can be adjusted from 1 mV per division to 100 mV per division, with eight vertical divisions representing full scale.

The channel has a DC offset range of ±500 mV and a dynamic range of ±400 mV relative to the selected channel offset. The maximum safe electrical input is 16 dBm peak AC with up to ±2 V DC.

Suitable coaxial cables, adapters, and torque practices should be used with the precision 3.5 mm interface. Damaged or incompatible RF connectors can degrade bandwidth, introduce reflections, and damage the module input.

Dedicated Trigger Input

The HP 83481A includes a separate trigger input with approximately 2.5 GHz bandwidth. The trigger input has a nominal impedance of 50 ohms and uses a 3.5 mm male connector.

The characteristic trigger-level range is ±1 V. Maximum safe input is ±2 V DC plus AC peak, with a maximum peak AC level of +16 dBm.

A dedicated trigger input allows the optical or electrical measurement waveform to be synchronized with an available clock or data signal. Trigger performance also depends on the connected mainframe and acquisition configuration.

Compatible Mainframes

The HP 83481A is designed for use with the HP 83480A Digital Communications Analyzer and the HP 54750A Digitizing Oscilloscope mainframes.

Use with an HP 54750A may require the appropriate communications firmware upgrade. The HP 83480K communications firmware kit was specified for bringing supported HP 54750A mainframes to the required compatibility level.

The mainframe provides the display, sampling system, controls, timebase, marker functions, measurements, storage, and remote interface required to operate the plug-in module. The HP 83481A does not function as a standalone instrument.

Typical Applications

The HP 83481A Option 040 is suitable for professional applications such as:

  • 155 Mb/s STM-1 and OC-3 transmitter testing
  • 622 Mb/s STM-4 and OC-12 transmitter testing
  • SONET and SDH waveform compliance measurements
  • Optical transmitter waveform characterization
  • 1310 nm and 1550 nm optical signal analysis
  • Average optical power measurement
  • High-speed electrical waveform measurements
  • Optical receiver and transceiver development
  • Telecommunications component evaluation
  • Production and quality-control testing
  • Laboratory research and troubleshooting
  • Digital communications system development

Product Overview

Brand HP
Model 83481A
Option 040
Product Category Optical/Electrical DCA Plug-In Module
Optical Channel Calibrated optical waveform and average power measurement
Option 040 Filter 155/622 Mb/s SONET/SDH reference receiver
Electrical Channel Selectable 12.4 GHz or 20 GHz bandwidth
Trigger Channel 2.5 GHz electrical trigger input
Compatible Mainframes HP 83480A and compatible HP 54750A mainframes
Primary Application Optical and electrical waveform analysis for high-speed digital communications

 

Optical Channel Specifications

Specification Details
Unfiltered Bandwidth DC to 2.85 GHz specified; DC to 3.0 GHz characteristic
Option 040 Filtered Data Rates 155 Mb/s and 622 Mb/s
Reference Receiver Standards ITU-T G.957 and GR-253-CORE for STM-1/OC-3 and STM-4/OC-12
Calibrated Wavelengths 1310 nm and 1550 nm
Supported Wavelength Range 1000 nm to 1600 nm
Compatible Fiber 9/125 µm single-mode fiber
Maximum Specified CW Peak Input 0.6 mW or -2.2 dBm
Maximum Specified Modulated Peak Input 0.4 mW or -4 dBm
Maximum Safe Input 10 mW peak
Unfiltered Transition Time 245 ps or less
Input Return Loss 33 dB with HMS-10 connector

 

Optical Scaling and Power Monitor Specifications

Specification Details
Minimum Optical Scale 5 µW per division
Maximum Optical Scale 100 µW per division
DC Offset Range +0.2 mW to -0.6 mW
Average Power Monitor Range -30 dBm to -4 dBm, approximately 1 µW to 400 µW
Factory-Calibrated Power Accuracy ±5% of reading, ±100 nW, and connector uncertainty from 20 °C to 30 °C
User-Calibrated Power Accuracy ±2% of reading, ±100 nW, and power meter uncertainty for temperature changes below 5 °C

 

Electrical Channel Specifications

Specification 12.4 GHz Mode 20 GHz Mode
Bandwidth DC to 12.4 GHz DC to 20 GHz
Calculated Transition Time 28.2 ps or less 17.5 ps or less
Maximum RMS Noise 0.5 mV 1 mV
Typical RMS Noise 0.25 mV 0.5 mV
Single-Marker Reading Accuracy ±1.5% of reading minus channel offset ±3% of reading minus channel offset

 

Electrical Input and Trigger Specifications

Specification Electrical Measurement Channel Trigger Input
Nominal Impedance 50 ohms 50 ohms
Connector 3.5 mm male 3.5 mm male
Bandwidth 12.4 GHz or 20 GHz 2.5 GHz
Maximum Safe Input 16 dBm peak AC with ±2 V DC 16 dBm peak AC with ±2 V DC
Trigger-Level Range Not applicable ±1 V characteristic
Electrical Dynamic Range ±400 mV relative to channel offset Not applicable
Electrical DC Offset Range ±500 mV Not applicable

 

Physical and Environmental Specifications

Specification Details
Operating Temperature 15 °C to 35 °C
Non-Operating Temperature -40 °C to 70 °C
Operating Humidity Up to 90% relative humidity, non-condensing, below 35 °C
Non-Operating Humidity Up to 95% relative humidity, non-condensing, below 65 °C
Net Weight Approximately 1.2 kg or 2.6 lb
Shipping Weight Approximately 2.1 kg or 4.6 lb
Power Requirements Supplied by the compatible DCA mainframe

 

Calibration Before Shipment

The recommended calibration interval for the HP 83481A is 12 months. When calibration service is technically applicable and supported, the module can be calibrated before shipment with a compatible HP 83480A or HP 54750A mainframe.

Calibration may include verification of the optical channel at 1310 nm and 1550 nm, average optical power monitoring, Option 040 filter response, electrical vertical accuracy, electrical bandwidth selection, channel offset, trigger operation, and communication with the mainframe.

A user vertical calibration is recommended after every ten hours of continuous use or when the operating temperature has changed by more than 2 °C since the previous vertical calibration. A 60-minute warm-up is required before applying the published optical and electrical specifications.

Calibration scope, measurement points, mainframe used, uncertainty, certificate type, recorded data, and optical connector configuration should be confirmed when formal documentation is required.

Buyer Considerations

Buyers should confirm that the module includes Option 040 and verify the installed optical connector adapter. The universal optical interface may be configured with different removable adapters, and an HMS-10, FC/PC, SC, ST, DIN, or other adapter should not be assumed to be included.

The HP 83481A requires a compatible HP 83480A or firmware-compatible HP 54750A mainframe. The mainframe, optical adapter, electrical cables, probes, power meter, optical source, calibration equipment, and other accessories may be required separately.

The optical input should be inspected for contamination and physical damage. The 3.5 mm electrical and trigger connectors should also be checked for damaged threads, bent contacts, excessive wear, or evidence of incompatible cable use.

Only the optical/electrical module, optical adapter, coaxial cables, optical patch cords, probes, mainframe, software, calibration documentation, and accessories specifically identified in the product listing should be considered included.

Why Buy from AssetRelay?

AssetRelay supplies professional equipment and product solutions for fiber optic, telecom, laboratory, production, electronic test, RF/microwave, photonics, inspection, cleaning, and digital communications applications. The HP 83481A Option 040 supports engineers, laboratories, production facilities, service organizations, and technical procurement teams requiring combined optical and electrical waveform analysis.

Buyers should review the product photographs, physical condition, Option 040 configuration, optical adapter, connector condition, DCA mainframe compatibility, optical and electrical performance, included accessories, calibration status, and testing information before purchase.

Read moreShow less
Product Details
83481Aopt040
Terms and Conditions

Settings

Click for more products.
No products were found.

Menu