The JDS Uniphase HA1593-FPL2 HA1 High-Resolution Programmable Optical Attenuator is a professional optical test instrument designed for precise optical power control in fiber optic, telecom, photonics, laboratory, and production test environments. The HA1 model is the high-resolution member of the JDS Uniphase HA Series programmable attenuator family and is intended for demanding applications that require fine attenuation control, repeatable settings, and reliable automated test capability.
The HA1 attenuator supports a 1200 nm to 1700 nm operating wavelength range, a 100 dB attenuation range, and 0.001 dB attenuation resolution. This makes the HA1593-FPL2 suitable for optical receiver testing, power meter linearity calibration, bit error rate testing, analog transmission tests, loss simulation in fiber optic links, EDFA output power characterization, and general laboratory optical power control.
The JDS Uniphase HA1593-FPL2 HA1 High-Resolution Programmable Optical Attenuator provides practical value for professional users who require accurate and repeatable attenuation control for fiber optic test and measurement workflows.
The JDS Uniphase HA1593-FPL2 HA1 is designed for optical test environments where accurate signal attenuation is required over a broad single-mode wavelength range. Programmable attenuation is useful when engineers and technicians need to simulate network loss, verify receiver performance, calibrate power measurement equipment, or control optical power delivered to a device under test.
The HA1 model provides ultra-high attenuation resolution compared with standard HA Series configurations, making it especially useful for applications where very small attenuation changes can affect measurement results. This is important in bit error rate testing, analog transmission tests, optical power meter linearity checks, and high-dynamic-range fiber optic experiments.
The instrument can be operated from the front panel or remotely through GPIB and RS232 interfaces. The SCPI-compatible command set supports integration into automated optical test systems where attenuation values must be set, changed, or swept as part of a repeatable test sequence. This makes the HA1593-FPL2 a practical choice for laboratory benches, production test stations, and engineering validation setups.
The JDS Uniphase HA1593-FPL2 HA1 High-Resolution Programmable Optical Attenuator is suitable for professional applications such as:
| Brand | JDS Uniphase |
| Model | HA1593-FPL2 |
| Base Model | HA1 |
| Product Category | High-Resolution Programmable Optical Attenuator |
| Primary Application | Precision optical attenuation and optical power control |
| Suitable For | Fiber optic laboratories, telecom test environments, photonics systems, production test stations, and automated optical measurement systems |
| Specification | HA1 Details |
| Operating Wavelength Range | 1200 nm to 1700 nm |
| Attenuation Range | 100 dB |
| Attenuation Resolution | 0.001 dB |
| Attenuation Repeatability | ±0.01 dB |
| Attenuation Change Rate | Less than 2.5 seconds from 0 dB to 100 dB |
| Attenuation Accuracy | ±0.1 dB |
| Single-Mode Insertion Loss | Less than 1.5 dB |
| Single-Mode Analog Return Loss | Greater than 60 dB |
| Maximum Optical Input Power | 200 mW |
| Recommended Recalibration Period | 2 years |
| Polarization Dependent Loss | 0.03 dB typical, 0.08 dB maximum |
| Beam Block Attenuation | Greater than 90 dB |
| Remote Control Interfaces | GPIB and RS232 |
| Command Set | SCPI-compatible command set |
| Specification | Details |
| Input Voltage | 90 V AC to 240 V AC, 50 Hz to 60 Hz |
| Power Consumption | 80 VA maximum |
| Dimensions | 21.2 cm x 8.9 cm x 35.5 cm |
| Rack Mounting | 19-inch rack-mounting, 2U high |
| Weight | 4 kg |
| Operating Temperature | 0 °C to 40 °C |
| Storage Temperature | -40 °C to 60 °C |
| Humidity | Maximum 90% up to 40 °C |
The JDS Uniphase HA1593-FPL2 HA1 can be used in optical test systems that require programmable attenuation control from either the front panel or remote interfaces. GPIB and RS232 connectivity make the instrument suitable for automated test sequencing, laboratory control systems, and production measurement workflows where repeatable optical power control is required.
The SCPI-compatible command set supports software-controlled test setups, allowing users to automate attenuation changes during receiver sensitivity tests, loss simulations, calibration routines, or optical component characterization procedures.
This description uses the HA1 specifications only. Buyers should confirm the exact physical configuration of the HA1593-FPL2 unit, including installed connector type, fiber interface, calibration status, included accessories, rack mounting hardware, condition notes, and remote interface functionality before purchase.
Because HA Series attenuators can exist in multiple configurations, buyers replacing an existing attenuator should confirm that the HA1593-FPL2 matches the intended wavelength range, attenuation range, connector setup, fiber type, return loss requirement, and automation needs of the optical test system.
AssetRelay supplies professional equipment and product solutions for fiber optic, telecom, laboratory, production, inspection, cleaning, RF/microwave, electronic test, and photonics applications. This product is listed to help technical buyers, procurement teams, engineers, installers, and service organizations source practical equipment for demanding professional environments.
When available, buyers should review the provided specifications, compatibility details, condition notes, and accessories before purchase to confirm that the product meets their application requirements.
Please sign in first.
Sign in