Gentec-EO UP55N-100H-H9-D0 100 W Broadband Thermopile Laser Power Detector Head

The Gentec-EO UP55N-100H-H9-D0 is a heatsink-cooled thermopile detector head for continuous-wave and average laser power measurements up to 100 W. It features a 55 mm aperture, broadband H9 absorber, 0.19 µm to 20 µm spectral range, and a smart DB-15 connector for compatible Gentec-EO power meters. The detector supports intermittent measurements up to 200 W for one minute, provides a typical 2-second rise time with anticipation, and is suitable for laser manufacturing, laboratory testing, optical system development, maintenance, and production quality control.

Download the Gentec-EO UP55N-100H-H9-D0 Specification Sheet (PDF)

Read moreShow less

Request Pricing

5 1
,
5/ 5
Yes, we have 1 in stock
Reference:
UP55N-100H-H9-X
Brand:
Description

Gentec-EO UP55N-100H-H9-D0 100 W Broadband Thermopile Laser Power Detector Head

The Gentec-EO UP55N-100H-H9-D0 is a heatsink-cooled thermopile detector head designed for continuous-wave and average laser power measurements up to 100 W. It combines a large 55 mm aperture, a broadband H9 absorber, passive heatsink cooling, and a smart DB-15 connector for operation with compatible Gentec-EO laser power meters.

The detector provides a broad spectral response from 0.19 µm to 20 µm, supporting ultraviolet, visible, near-infrared, and infrared laser measurement applications. Its standard calibrated spectral range extends from 0.248 µm to 2.1 µm. Additional calibration may be available for either the 2.1 µm to 2.5 µm range or at 10.6 µm.

The UP55N-100H-H9-D0 measures as much as 100 W of continuous average optical power and supports intermittent measurements up to 200 W for one minute when followed by the required cooling interval. The large aperture and heatsink construction make the detector well suited for laser manufacturing, research, production testing, optical alignment, system integration, maintenance, and high-power photonics applications.

Features and Benefits of the Gentec-EO UP55N-100H-H9-D0

  • 100 W continuous power capacity: Measures continuous-wave and average laser power up to 100 W.
  • 200 W intermittent capability: Supports measurements up to 200 W for one minute when followed by a minimum three-minute cooling interval.
  • Large 55 mm aperture: Accommodates broad free-space beams and simplifies alignment in compatible high-power optical systems.
  • Broad spectral response: Operates from 0.19 µm to 20 µm for ultraviolet, visible, near-infrared, and infrared laser applications.
  • Calibrated wavelength range: Provides standard calibration from 0.248 µm to 2.1 µm.
  • H9 broadband absorber: Offers a broad and relatively flat response for general-purpose laser power measurement.
  • Passive heatsink cooling: Supports continuous high-power operation without a fan or external cooling-water supply.
  • Smart DB-15 interface: Stores detector identification, calibrated sensitivity, available scales, and wavelength correction data.
  • Automatic meter configuration: Compatible Gentec-EO monitors can recognize the detector and apply the stored calibration information.
  • Fast thermopile response: Provides a typical 0% to 95% rise time of 2 seconds with compatible anticipation processing.
  • Measurement repeatability: Offers specified repeatability of ±0.5% under the documented conditions.
  • Optional pulse-energy capability: Supports Single-Shot Energy measurements when paired with compatible equipment and operated within the specified limits.

Broadband Thermopile Laser Power Measurement

The UP55N-100H-H9-D0 uses thermopile sensing technology to measure incident optical power. The broadband absorber converts incoming laser energy into heat, and the detector generates a low-level electrical signal proportional to the absorbed average power.

Thermopile detectors provide broader spectral coverage than wavelength-limited semiconductor photodiodes. This allows one detector to support multiple laser types across ultraviolet, visible, and infrared wavelength regions, provided the source remains within the detector’s calibrated wavelength range, total power rating, power-density limits, and pulse-energy limits.

The detector is designed primarily for continuous-wave and average power measurements. It can also measure the average power of pulsed lasers when the repetition rate, pulse duration, beam size, average power, and pulse energy density remain within the supported operating conditions.

100 W Continuous Laser Power Capability

The Gentec-EO UP55N-100H-H9-D0 supports continuous average laser power measurements up to 100 W. Its integrated heatsink dissipates absorbed thermal energy without requiring an external fan or water-cooling system.

The heatsink fins should remain vertical during operation to promote effective natural convection. Adequate clearance should be maintained around the detector so air can move freely through the fins. Blocking airflow or placing the detector in an enclosed space can increase operating temperature and affect measurement stability.

The continuous power rating applies only when the laser beam remains within the documented average power-density limits. Total power and power density must both be evaluated before the beam is applied.

200 W Intermittent Power Operation

The detector supports intermittent measurements up to 200 W for a maximum duration of one minute. After an elevated-power measurement, a minimum cooling interval of three minutes is required before another measurement at the intermittent level is performed.

The intermittent specification does not increase the absorber’s average power-density or pulse-energy-density limits. A small or highly focused beam may damage the absorber even when the total incident power remains below 200 W.

Repeated operation above the 100 W continuous rating without the required cooling interval can cause excessive heating, measurement drift, reduced repeatability, or permanent damage to the absorber and detector assembly.

Large 55 mm Aperture

The UP55N-100H-H9-D0 provides a 55 mm aperture for measuring compatible free-space laser beams. The large opening is useful for expanded beams, high-power laser systems, optical alignment stations, and applications in which a smaller aperture could clip part of the beam.

The entire optical beam must remain within the active absorber area. Beam clipping can cause an inaccurate low reading while exposing the detector housing or aperture structure to damaging laser power.

For optimum accuracy, the beam should be centred on the detector and should have a diameter similar to the beam used during calibration. The individual calibration certificate should be reviewed for detector-specific beam geometry and calibration information.

H9 General-Purpose Broadband Absorber

The H9 designation identifies the detector’s general-purpose broadband absorber. The H absorber provides a broad and relatively flat spectral response for laser power measurement across multiple wavelength regions.

The absorber supports a spectral response from 0.19 µm to 20 µm. The standard calibrated response extends from 0.248 µm to 2.1 µm, with wavelength-dependent uncertainty values defined for specific portions of that range.

The H9 absorber is a diffusive optical surface. Approximately 5% to 15% of the incident laser energy may be diffusely reflected rather than absorbed. Suitable laser safety eyewear, barriers, beam enclosures, protective sleeves, and other controls should be used for the operating wavelength and power.

Spectral Range and Calibration Options

The detector has a broadband spectral response extending from 0.19 µm to 20 µm. Its standard calibrated spectral range extends from 0.248 µm to 2.1 µm.

Additional calibration may be available for either wavelengths from 2.1 µm to 2.5 µm or at 10.6 µm. Both extra calibration options cannot be applied to one detector under the documented configuration.

Additional wavelength calibration should not be assumed to be present unless it is identified on the detector’s calibration certificate. Measurements outside the supplied calibrated range may require a suitable correction or recalibration before traceable results can be reported.

Smart DB-15 Connector

The D0 configuration uses the standard Gentec-EO smart DB-15 male connector. An EEPROM inside the connector stores detector information, including the model, calibration sensitivity, applicable measurement scales, and wavelength correction factors for as many as 20 wavelengths.

When connected to a compatible Gentec-EO display, the monitor can identify the detector and automatically configure its measurement parameters. This helps reduce setup time and limits errors associated with manually entering detector sensitivity information.

The attached flexible cable has a standard length of approximately 180 cm. The detector should not be carried, suspended, or repositioned using the cable because this can damage the conductors, strain relief, connector, or internal connections.

Compatible Gentec-EO Power Meters

The smart DB-15 connector is intended for compatible Gentec-EO laser power and energy meter displays. The power meter reads the thermopile output and uses calibration information stored in the detector connector to calculate the incident optical power.

Depending on the connected monitor, available functions may include automatic detector recognition, wavelength correction, zero offset, anticipation, measurement scaling, statistics, data logging, analog output, graphical displays, and computer communication.

The UP55N-100H-H9-D0 is a detector head and does not contain an integrated display. A compatible meter is required unless the detector is connected to a suitable precision microvoltmeter or data-acquisition system.

Response Time and Anticipation

The detector provides a typical 0% to 95% rise time of 2 seconds when used with compatible anticipation processing. Its natural 0% to 95% rise time is 11 seconds.

Anticipation uses detector response data and mathematical processing to estimate the stabilized power reading faster than the natural thermal response. This can improve efficiency during laser alignment, production testing, power adjustment, and repeated measurements.

The documented power noise is ±10 mW with anticipation and ±5 mW without anticipation. Disabling anticipation may produce a quieter reading when maximum response speed is not required.

Sensitivity, Linearity, and Repeatability

The typical sensitivity of the UP55N-100H-H9-D0 is 0.12 mV/W. The exact sensitivity is specific to the individual detector and should be obtained from its calibration certificate or smart DB-15 memory.

Linearity with power is specified at ±2%. Repeatability is specified at ±0.5%, and linearity versus beam dimension is specified at ±0.5% under the documented operating and calibration conditions.

Measurement performance can be influenced by absorber condition, beam placement, beam dimensions, wavelength selection, thermal stabilization, ambient airflow, detector orientation, connected monitor, and calibration status.

Calibration Uncertainty by Wavelength

Calibration uncertainty depends on the operating wavelength. The documented uncertainty is ±2.5% from 1064 nm to 1070 nm, ±4.3% from 248 nm to 299 nm, ±3.3% from 300 nm to 1565 nm, and ±4.2% from 1566 nm to 2100 nm.

These uncertainty values include linearity with power and apply under the documented calibration conditions. The specifications are based on a one-year calibration cycle, an operating temperature from 15 °C to 28 °C, and relative humidity not exceeding 80%.

The individual detector certificate should be consulted for its calibrated sensitivity, wavelength correction information, calibration conditions, and other unit-specific details.

Power Density and Beam Diameter

The detector’s total power rating must be considered together with its maximum average power density. At 1.064 µm with a 10 W continuous-wave beam, the documented maximum average power density is 45 kW/cm². At 10.6 µm with a 10 W continuous-wave beam, the documented maximum is 14 kW/cm².

The limits are specified for the stated wavelengths, powers, and operating conditions. The allowable power density can vary with wavelength, beam profile, total power, exposure time, absorber condition, and localized hot spots.

The incident beam area should not be smaller than 10% of the detector aperture. A tightly focused beam can cause excessive localized heating and absorber damage even when the total optical power remains below the 100 W continuous rating.

Pulsed Laser Damage Thresholds

The UP55N-100H-H9-D0 can measure the average power of pulsed sources when the beam remains within its total power and pulse-energy-density limits.

For 1064 nm radiation with 360 µs pulses at 5 Hz, the documented pulsed damage threshold is 9 J/cm². For 7 ns pulses at 10 Hz, the documented limits are 1.0 J/cm² at 1064 nm, 0.6 J/cm² at 532 nm, and 0.3 J/cm² at 266 nm.

Pulse energy density must be calculated using the energy delivered to the illuminated absorber area. A pulsed laser can remain below the average power rating while exceeding the damage threshold because of high pulse energy, peak power, or local beam intensity.

Pulse duration, repetition rate, beam profile, beam diameter, wavelength, hot spots, and total exposure time should be evaluated before the source is applied to the detector.

Optional Single-Shot Energy Mode

The UP55N H9 detector family supports an optional Single-Shot Energy mode when used with a compatible Gentec-EO monitor or suitable data-acquisition equipment. This mode allows individual laser pulses to be measured within the documented operating limits.

Typical sensitivity in Single-Shot Energy mode is 0.028 mV/J. The typical rise time is 1300 ms, the minimum repetition period is 11.1 seconds, and the maximum pulse width is 433 ms.

The documented maximum measurable energy is 200 J for a 1064 nm source with 360 µs pulses. Noise-equivalent energy is 250 mJ, and the documented accuracy is ±5%.

Single-Shot Energy capability depends on the detector configuration, connected monitor, enabled operating mode, wavelength, pulse duration, repetition period, beam diameter, and energy density. Compatibility should be verified before the detector is selected for pulse-energy measurements.

Measurement Without a Gentec-EO Monitor

The detector can be used with a suitable precision microvoltmeter or data-acquisition system instead of a Gentec-EO display. The connected voltage-measurement instrument should provide a load impedance greater than 100 kO.

The expected detector output voltage can be determined by multiplying the applied optical power by the detector’s calibrated sensitivity:

Output voltage = incident power x calibrated detector sensitivity

Measured laser power can be calculated using the following relationship:

Measured power = (illuminated output voltage - zero output voltage) / calibrated detector sensitivity

The exact sensitivity from the individual calibration certificate should be used. The published value of 0.12 mV/W is a typical specification and may differ from the calibrated sensitivity of a particular detector.

Typical Applications

  • Continuous-wave laser power measurement
  • Average power measurement of pulsed lasers
  • High-power free-space optical testing
  • Ultraviolet, visible, and infrared laser evaluation
  • Laser source alignment and adjustment
  • Laser output stability monitoring
  • Optical component characterization
  • Laser manufacturing and quality assurance
  • Production-line power verification
  • Laser system service and maintenance
  • Photonics laboratory research
  • Optional single-shot energy measurement

Product Overview

Brand Gentec-EO
Model UP55N-100H-H9-D0
Product Category Thermopile Laser Power Detector Head
Maximum Continuous Power 100 W
Maximum Intermittent Power 200 W for one minute
Aperture Diameter 55 mm
Absorber H9 general-purpose broadband absorber
Cooling Passive heatsink
Output Connection D0 smart DB-15 male connector
Primary Application Broadband continuous-wave and average laser power measurement up to 100 W

 

Optical and Measurement Specifications

Specification Details
Detector Technology Thermopile
Aperture Diameter 55 mm
Spectral Range 0.19 µm to 20 µm
Standard Calibrated Spectral Range 0.248 µm to 2.1 µm
Available Additional Calibration Either 2.1 µm to 2.5 µm or 10.6 µm
Maximum Continuous Average Power 100 W
Maximum Intermittent Power 200 W for one minute
Minimum Cooling Interval After Intermittent Use Three minutes
Typical Rise Time 2 seconds from 0% to 95%
Natural Rise Time 11 seconds from 0% to 95%
Typical Sensitivity 0.12 mV/W
Power Noise with Anticipation ±10 mW
Power Noise without Anticipation ±5 mW

 

Accuracy and Repeatability Specifications

Specification Details
Calibration Uncertainty at 1064 to 1070 nm ±2.5%
Calibration Uncertainty at 248 to 299 nm ±4.3%
Calibration Uncertainty at 300 to 1565 nm ±3.3%
Calibration Uncertainty at 1566 to 2100 nm ±4.2%
Linearity with Power ±2%
Repeatability ±0.5%
Linearity versus Beam Dimension ±0.5%

 

Power Density and Pulsed Damage Thresholds

Operating Condition Documented Limit
Maximum Average Power Density at 1.064 µm and 10 W CW 45 kW/cm²
Maximum Average Power Density at 10.6 µm and 10 W CW 14 kW/cm²
1064 nm, 360 µs, 5 Hz 9 J/cm²
1064 nm, 7 ns, 10 Hz 1.0 J/cm²
532 nm, 7 ns, 10 Hz 0.6 J/cm²
266 nm, 7 ns, 10 Hz 0.3 J/cm²

 

Single-Shot Energy Specifications

Specification Details
Typical Energy Sensitivity 0.028 mV/J
Power-to-Energy Sensitivity Ratio 4.25 J/W
Typical Rise Time in SSE Mode 1300 ms
Minimum Repetition Period 11.1 seconds
Maximum Pulse Width 433 ms
Maximum Measurable Energy 200 J at 1064 nm with 360 µs pulses
Noise-Equivalent Energy 250 mJ
Documented SSE Accuracy ±5%

 

Physical and Environmental Specifications

Specification Details
Cooling Method Passive heatsink
Dimensions 89 mm high x 89 mm wide x 106 mm deep
Detector Head Weight Approximately 0.93 kg
Standard Cable Length Approximately 180 cm
Specified Calibration Environment 15 °C to 28 °C and relative humidity not exceeding 80%
Storage Temperature 10 °C to 65 °C
Maximum Storage Humidity 90% relative humidity
Calibration Cycle One year for the documented specifications

 

Model Number Configuration

Model Element Configuration
UP Radial thermopile laser power detector series
55N UP55N enclosure with a 55 mm aperture
100H 100 W continuous power rating with heatsink cooling
H9 General-purpose broadband absorber
D0 Standard smart DB-15 connector without an integrated meter

 

Measurement Setup and Alignment

The detector should be secured on a stable optical stand or mounting system before the protective cover is removed. The heatsink fins should remain vertical, and sufficient clearance should be provided for natural airflow.

The detector should be allowed to thermally stabilize for at least 10 minutes before measurements begin. Initial optical alignment should be performed using a safely reduced laser power.

The beam should be centred on the absorber and kept completely within the 55 mm opening. The illuminated area should not be smaller than 10% of the detector aperture.

After alignment, the laser can be applied for approximately one minute to help stabilize the detector. The beam should then be blocked, and the output should be allowed to settle before the connected monitor’s zero-offset function is used.

Once the detector is zeroed, the beam can be reapplied. For optimum measurement confidence, the reading should be allowed to stabilize before the final value is recorded.

Thermal and Environmental Considerations

Thermopile detectors respond to heat from the laser and can also be affected by changes in the surrounding thermal environment. Drafts, nearby heat sources, rapid temperature changes, direct sunlight, and physical contact with the detector can influence low-level measurements.

The heatsink should not be covered or placed against a surface that restricts airflow. The detector can become hot during high-power operation and should be allowed to cool before handling.

The detector should be stored between 10 °C and 65 °C with relative humidity not exceeding 90%. A protective cover should remain installed over the absorber during storage and transport.

Detector Care and Laser Safety

The absorber surface should be protected from dust, liquids, fingerprints, oil, and other contamination. Contamination can change local absorption, alter measurement response, and increase the risk of permanent damage.

The absorber should not be touched or cleaned unless an appropriate manufacturer-approved procedure is available. Even minor mechanical contact can scratch or alter the calibrated optical surface.

A portion of the incident laser beam is diffusely reflected from the H9 absorber. Protective eyewear and engineering controls should account for both the incoming beam and reflected radiation.

The detector should not be carried by its attached cable. The cable, strain relief, smart connector, and connector locking hardware should be protected from pulling, crushing, sharp bends, and impact.

Calibration Before Shipment

When selected, the Gentec-EO UP55N-100H-H9-D0 can be calibrated before shipment using suitable laser power standards and compatible measurement equipment. Calibration may include detector sensitivity, power linearity, repeatability, wavelength response, zero stability, rise time, and smart DB-15 recognition.

Calibration should identify the detector model, serial number, test wavelength, incident power, beam diameter, connected meter, environmental conditions, recorded results, and measurement uncertainty.

Buyers requiring calibration at a particular wavelength should confirm whether the wavelength falls within the standard 0.248 µm to 2.1 µm calibrated range or requires optional calibration from 2.1 µm to 2.5 µm or at 10.6 µm.

Comprehensive Functional and Performance Testing

The Gentec-EO UP55N-100H-H9-D0 receives comprehensive functional and performance testing before shipment. Testing may include inspection of the H9 absorber, 55 mm aperture, heatsink, enclosure, attached cable, strain relief, smart DB-15 connector, connector memory, and detector identification.

Electrical testing may include signal continuity, zero stability, smart-head recognition, sensitivity response, and compatibility with an available Gentec-EO laser power meter.

Optical testing may include response to a suitable laser source, displayed power comparison against calibrated reference equipment, response stability, anticipation operation, repeatability, and wavelength correction when suitable standards are available.

The exact testing scope depends on the detector condition, available laser wavelengths, required power levels, calibration status, compatible meter, reference detector, beam geometry, and requested test points.

Buyer Considerations

Buyers should confirm that the detector is the complete Gentec-EO UP55N-100H-H9-D0 configuration. Other UP55 models may use different power ratings, cooling methods, absorbers, or connector types.

The H9 absorber should be inspected for contamination, scratches, burns, coating damage, discoloration, or other conditions that may affect measurement performance. Slight discoloration does not automatically indicate a calibration problem, but significant damage may require repair and recalibration.

The attached cable, strain relief, smart DB-15 connector, heatsink fins, aperture, enclosure, calibration label, protective cover, and mounting provisions should also be reviewed.

A compatible Gentec-EO monitor is required to display measurements unless the detector is connected to a suitable high-impedance microvoltmeter or data-acquisition system.

Only the detector head, protective cover, calibration certificate, Personal Wavelength Correction certificate, compatible power meter, optical stand, extension cable, storage case, and accessories specifically identified in the product listing should be considered included.

Why Buy from AssetRelay?

AssetRelay supplies professional equipment and product solutions for laser measurement, photonics, optical test, fiber optics, telecom, laboratory, production, electronic test, RF/microwave, inspection, and technical research applications. The Gentec-EO UP55N-100H-H9-D0 provides broadband high-power laser measurement capability for laboratories, laser manufacturers, production facilities, research teams, service organizations, and optical system integrators.

Buyers should review the product photographs, absorber condition, complete model number, heatsink condition, attached cable, smart DB-15 connector, calibration status, required wavelength, anticipated power and power density, compatible meter, functional test results, and included accessories before purchase.

Read moreShow less