The HP E5574A-015-020 is an optical loss analyzer configured with a 1550 nm Fabry-Perot laser source and bare fiber pigtail output. It is designed for insertion loss, optical gain, polarization-dependent loss, polarization-dependent gain, and polarization-dependent crosstalk characterization of active and passive fiber optic components. The analyzer provides 0.0001 dB display resolution, a 0 dB to 5 dB PDL/PDG/PDCR measurement range, and support for devices with up to 20 dB insertion loss. Compatible optical heads, connector adapters, and a polarization controller are required according to the intended measurement setup.
Request Pricing
The HP E5574A-015-020 is a precision optical loss analyzer configured for characterization of active and passive fiber optic components at 1550 nm. Option 015 provides an integrated 1550 nm Fabry-Perot laser source, while Option 020 provides a bare fiber pigtail optical output for flexible connection to compatible test fixtures, fibers, and devices under test.
The HP E5574A brings several optical measurement functions together in one instrument. It is designed to characterize insertion loss, optical gain, polarization-dependent loss, polarization-dependent gain, and polarization-dependent crosstalk. These capabilities support optical component development, incoming inspection, production testing, device qualification, process engineering, and photonics research.
The analyzer is particularly useful for devices whose optical transmission or gain changes with the input state of polarization. It can measure the different contributions to the total loss or gain of a device without requiring a separate PDL reference measurement. This integrated approach helps simplify the optical setup while supporting manual bench measurements and automated production workflows.
Option 015 equips the HP E5574A with an integrated 1550 nm Fabry-Perot laser source. The 1550 nm region is widely used for long-haul telecommunications, erbium-doped fiber amplifiers, WDM systems, passive C-band components, and other single-mode fiber optic applications.
The integrated source allows supported measurements to be performed without requiring a separate external laser for routine 1550 nm testing. This helps simplify the optical setup and can reduce the number of instruments and connections needed for component characterization.
The Fabry-Perot source is suitable for supported loss, gain, and polarization measurements at its configured wavelength. Applications requiring swept-wavelength characterization can use a compatible external tunable laser or broadband source within the analyzer’s supported external-source range.
Option 020 provides a bare fiber pigtail optical output. This configuration allows the analyzer output to be fusion spliced to a compatible test lead, connected through a suitable bare-fiber fixture, or terminated according to the requirements of a specialized optical setup.
A pigtailed output helps avoid the additional connector effects that can be introduced by a removable optical interface. This can be useful for polarization-dependent testing where connector movement, reflection, loss, and mechanical stress may affect measurement stability.
The bare fiber must be handled carefully. Tight bends, pulling, twisting, crushing, coating damage, contamination, or mechanical stress can increase optical loss and alter the state of polarization delivered to the device under test.
Any splice or temporary bare-fiber connection should be mechanically stable throughout the measurement process. The loss and polarization effects of the connection should be considered when establishing the optical reference.
The HP E5574A measures the optical loss introduced by passive components. Insertion loss is determined by comparing a reference optical power level with the power measured after the device under test is placed in the optical path.
The analyzer supports devices with insertion loss up to 20 dB. This capability is suitable for characterizing filters, couplers, splitters, attenuators, switches, isolators, circulators, connectors, splices, and other passive optical devices.
Accurate insertion-loss measurements require stable optical power, clean interfaces, compatible fiber, an appropriate optical head, and a controlled reference procedure. Fiber movement, connector contamination, unstable splices, and changing source conditions can affect the result.
The HP E5574A can characterize the gain of active optical devices by comparing the input and output optical power under defined operating conditions. Typical applications include erbium-doped fiber amplifiers, semiconductor optical amplifiers, and other active photonic components.
Active devices should be allowed to reach stable operating conditions before gain measurements are recorded. Input power, pump conditions, device bias, operating temperature, wavelength, and output loading should remain controlled throughout the test.
The installed optical head must support the expected output power. External attenuation may be required when an active device produces optical power above the supported input level of the selected measurement head.
Polarization-dependent loss is the change in insertion loss that occurs as the input state of polarization varies. PDL is an important performance parameter for passive optical components used in telecommunications, WDM, sensing, and photonics systems.
The HP E5574A supports PDL measurements from 0 dB to 5 dB. For measured PDL values up to 0.2 dB, absolute uncertainty is specified at ±0.005 dB with an additional asymmetric contribution of +0/-2.5% of the measured PDL.
For PDL values greater than 0.2 dB and up to 5 dB, absolute uncertainty is specified at ±0.005 dB with an additional asymmetric contribution of +0/-5% of the measured PDL.
PDL repeatability is specified at ±0.001 dB plus 2% of the measured PDL. The analyzer complies with Fiber-Optic Test Procedure FOTP-157 for applicable PDL measurements.
Polarization-dependent gain describes the change in optical gain of an active device as the input state of polarization varies. PDG testing is useful when evaluating optical amplifiers and other active devices that may respond differently to changing polarization conditions.
The HP E5574A supports PDG measurements from 0 dB to 5 dB. The documented PDL and PDG uncertainty specifications share the same measurement ranges and uncertainty structure.
PDG results can be influenced by changes in source power, amplifier pump level, temperature, wavelength, bias, and device operating conditions. These variables should remain stable so the measured variation represents polarization effects rather than unrelated drift.
The HP E5574A also supports polarization-dependent crosstalk ratio measurements. PDCR testing is useful for optical devices whose crosstalk or isolation changes with the input state of polarization.
For measured PDCR values up to 0.2 dB, absolute uncertainty is specified at ±0.01 dB with an additional asymmetric contribution of +0/-5% of the measured PDCR.
For PDCR values greater than 0.2 dB and up to 5 dB, absolute uncertainty is specified at ±0.01 dB with an additional asymmetric contribution of +0/-10% of the measured PDCR.
PDCR repeatability is specified at ±0.002 dB plus 4% of the measured PDCR.
The analyzer provides a display resolution of 0.0001 dB. This fine resolution helps operators observe small optical changes during component alignment, process adjustment, polarization analysis, and comparative testing.
Display resolution is not the same as absolute measurement accuracy. Overall measurement confidence also depends on the selected optical head, source stability, optical power, wavelength, reference procedure, polarization controller, device loss, connection quality, and environmental stability.
The HP E5574A can work with a compatible external tunable laser or white-light source for measurements requiring broader wavelength coverage. With a suitable external source, the documented measurement range extends from 1250 nm to 1600 nm.
External-source operation supports wavelength-dependent characterization of filters, couplers, switches, isolators, circulators, amplifiers, multiplexers, demultiplexers, and other components.
The external source must be compatible with the analyzer, optical head, polarization controller, fiber type, and intended measurement procedure. External sources and associated control hardware are included only when specifically identified in the product listing.
The E5574A supports interchangeable HP optical measurement heads selected according to wavelength and power requirements. Available head configurations cover selected wavelengths from 800 nm to 1700 nm and selected optical power levels from +27 dBm to -90 dBm.
For the highest documented PDL measurement performance between 1250 nm and 1600 nm, the HP 81521B Option 001 optical head is recommended.
One compatible HP 81000xA connector adapter is required for each optical head. The actual optical head and adapter installed with an individual analyzer should be confirmed before measurements are planned.
The analyzer’s complete measurement capability depends on the optical head. The source option alone does not establish detector wavelength coverage, detector power range, connector interface, or optical power accuracy.
Polarization-dependent measurements require a suitable polarization controller to vary the state of polarization applied to the device under test. The HP E5574A can be used with compatible HP lightwave polarization controllers such as the HP 11896A and HP 8169A.
The HP 11896A uses a fiber-loop architecture to generate all states of polarization while maintaining very low insertion-loss variation. It operates from 1250 nm to 1600 nm and provides insertion-loss variation below ±0.002 dB during adjustment.
The HP 8169A uses a built-in linear polarizer, quarter-wave plate, and half-wave plate to synthesize defined states of polarization. Its documented operating wavelength range is 1470 nm to 1570 nm, making it suitable for compatible 1550 nm applications.
A polarization controller is a separate instrument and should be considered included only when specifically identified in the product listing.
| Brand | HP |
| Base Model | E5574A |
| Configuration | E5574A-015-020 |
| Product Category | Optical Loss and Polarization Analyzer |
| Option 015 | 1550 nm Fabry-Perot laser source |
| Option 020 | Bare fiber pigtail optical output |
| Primary Measurements | Insertion loss, optical gain, PDL, PDG, and PDCR |
| Control Interface | HP-IB |
| Primary Application | 1550 nm loss, gain, and polarization characterization of active and passive optical components |
| Configuration Item | Details |
| Source Option | Option 015 |
| Integrated Source Wavelength | 1550 nm |
| Source Type | Fabry-Perot laser |
| Output Option | Option 020 |
| Optical Output | Bare fiber pigtail |
| Specification | Details |
| Display Resolution | 0.0001 dB |
| PDL/PDG/PDCR Measurement Range | 0 dB to 5 dB |
| Absolute PDL/PDG Uncertainty at 0 to 0.2 dB | ±0.005 dB with an additional +0/-2.5% of the measured PDL |
| Absolute PDL/PDG Uncertainty Above 0.2 to 5 dB | ±0.005 dB with an additional +0/-5% of the measured PDL |
| PDL/PDG Repeatability | ±0.001 dB plus 2% of the measured PDL |
| Absolute PDCR Uncertainty at 0 to 0.2 dB | ±0.01 dB with an additional +0/-5% of the measured PDCR |
| Absolute PDCR Uncertainty Above 0.2 to 5 dB | ±0.01 dB with an additional +0/-10% of the measured PDCR |
| PDCR Repeatability | ±0.002 dB plus 4% of the measured PDCR |
| Supported Test Procedure | Fiber-Optic Test Procedure FOTP-157 |
| Specification | Details |
| Integrated Test Wavelength | 1550 nm |
| External-Source Wavelength Range | 1250 nm to 1600 nm |
| Maximum Device Insertion Loss | 20 dB |
| Available Optical Head Wavelength Coverage | Selected configurations from 800 nm to 1700 nm |
| Available Optical Head Power Coverage | Selected configurations from +27 dBm to -90 dBm |
| Recommended High-Performance PDL Head | HP 81521B Option 001 for measurements from 1250 nm to 1600 nm |
| Documented Power Measurement Accuracy | 2.2% for the applicable system configuration |
| PDL Reference Measurement | Not required |
| Option | Description |
| 013 | 1310 nm Fabry-Perot laser source |
| 015 | 1550 nm Fabry-Perot laser source |
| 135 | Dual-wavelength laser source |
| 020 | Bare fiber pigtail output |
| 021 | Straight-contact connector output |
| 022 | Angled-contact connector output |
| 521 | Adds a second HP 81521B Option 001 optical head |
A compatible optical measurement head is required for the intended wavelength and optical power range. The E5574A source option does not identify the optical head installed in a particular analyzer.
One compatible HP 81000xA connector adapter is required for each optical head. An appropriate connector interface is also required for the optical measurement input according to the selected head and device-under-test connection.
The HP 81521B Option 001 optical head is recommended when the highest supported PDL performance is required between 1250 nm and 1600 nm. Optical heads, adapters, and interfaces should be considered included only when specifically identified in the listing.
The bare output pigtail should be inspected for coating damage, tight bends, cracks, previous splices, contamination, or mechanical stress. The fiber should be secured so movement does not change optical loss or polarization during measurement.
All connectorized input interfaces should be inspected and cleaned before use. Contamination can increase loss, reflection, instability, and measurement uncertainty.
The selected optical head must support the 1550 nm source and expected optical power. The device under test must remain within the analyzer’s documented 20 dB maximum insertion-loss capability.
Active devices should be allowed to stabilize before optical gain or PDG measurements are performed. Source power, device bias, pump conditions, temperature, and cable routing should remain controlled throughout the test.
When technically applicable and selected, the HP E5574A-015-020 can be calibrated or performance-verified before shipment. Calibration may include the 1550 nm source, optical power measurement, insertion-loss response, display operation, PDL/PDG measurement performance, PDCR measurement performance, and HP-IB communication.
A complete system calibration requires the analyzer, installed optical measurement head, connector adapter, bare fiber output connection, compatible polarization controller, reference cables, and appropriate optical standards. Calibration documentation should identify every measurement head by model and serial number.
Buyers requiring formal calibration should confirm the required optical power levels, insertion-loss points, PDL or PDG values, optical head configuration, pigtail termination, certificate type, recorded measurements, and measurement uncertainty before purchase.
The HP E5574A-015-020 receives comprehensive functional and performance testing before shipment. Evaluation may include power-up, display operation, control response, installed-option recognition, 1550 nm source selection, optical output, optical-head recognition, measurement functions, reference functions, and HP-IB communication.
Optical testing may include 1550 nm source verification, optical power response, insertion-loss measurement, gain measurement, PDL/PDG operation, PDCR operation, and measurement repeatability using suitable reference equipment.
The bare output pigtail, installed optical heads, connector adapters, input ports, and optical paths may be inspected for contamination, damaged fiber, worn interfaces, loose mounting, or other conditions that could affect measurement performance.
The exact test scope depends on the installed optical head, pigtail condition, connector adapters, polarization controller, available reference standards, and supporting optical measurement equipment.
Buyers should confirm the complete configuration as HP E5574A with Option 015 and Option 020. Option 015 identifies the 1550 nm Fabry-Perot source, while Option 020 identifies the bare fiber pigtail output.
The installed optical head or heads should be identified before purchase. The optical head determines the supported detector wavelength range, power range, connector adapter, and complete measurement capability.
The product listing should identify whether a polarization controller, optical heads, HP 81000-series adapters, optical cables, an external source, HP-IB cable, software, manuals, or calibration records are included.
The condition of the display, controls, 1550 nm source, output pigtail, optical heads, adapters, HP-IB interface, enclosure, cooling openings, power inlet, and identification labels should be reviewed before purchase.
Only the analyzer, installed source option, bare output pigtail, optical heads, connector adapters, polarization controller, cables, software, documentation, calibration records, and accessories specifically identified in the product listing should be considered included.
AssetRelay supplies professional equipment and product solutions for fiber optic, telecom, laboratory, production, optical test, photonics, electronic test, RF/microwave, inspection, and technical research applications. The HP E5574A-015-020 provides 1550 nm loss, gain, and polarization analysis for optical component manufacturers, telecommunications laboratories, amplifier developers, production facilities, system integrators, and research organizations.
Buyers should review the product photographs, complete option configuration, 1550 nm source operation, pigtail condition, installed optical heads, connector adapters, polarization-controller compatibility, calibration status, functional test results, and included accessories before purchase.