Agilent (HP/Keysight) 81600B Tunable Laser (S+C...
Agilent (HP/Keysight) 81600B 1370 to 1495nm TLS...
The Agilent 81600B Option 132 is a high-power O-band tunable laser source module covering wavelengths from 1260 nm to 1375 nm without mode hops. Designed for the Agilent 8164B Lightwave Measurement System, it provides 0.1 pm wavelength resolution, ±10 pm absolute wavelength accuracy, tuning speeds up to 80 nm/s, and output power reaching +9 dBm peak. A built-in real-time wavelength meter, polarization-maintaining fiber output, modulation capabilities, and coherence control support CWDM component characterization, optical filter testing, wavelength-resolved measurements, and automated photonics applications.
Download the Agilent 81600B Option 132 Specification Sheet (PDF)
The Agilent 81600B Option 132 is a high-power tunable laser source module designed for wavelength-resolved optical measurements across the O-band. It provides continuous, mode-hop-free tuning from 1260 nm to 1375 nm, supporting optical component characterization, CWDM testing, filter analysis, receiver evaluation, and fiber optic research near 1310 nm.
The module provides 0.1 pm wavelength-setting resolution, equivalent to approximately 17.7 MHz at 1300 nm. A built-in real-time wavelength meter supports an absolute wavelength accuracy of ±10 pm, with typical performance of ±2.5 pm in stepped operation under the documented calibration and environmental conditions.
The Option 132 is a high-power, single-output configuration. Maximum output reaches +9 dBm peak under typical conditions, with documented continuous output levels across defined portions of the tuning range. The source can sweep as fast as 80 nm/s while retaining specified wavelength performance.
The 81600B Option 132 is a plug-in module and requires the bottom slot of an Agilent 8164B Lightwave Measurement System mainframe. It does not operate as a standalone tunable laser. A compatible Agilent 81000xI Series connector interface is also required for the optical output.
The Agilent 81600B Option 132 covers wavelengths from 1260 nm to 1375 nm. This range includes the 1310 nm telecommunications region and supports testing of optical components used in O-band transmission systems.
The source is continuously tunable across its complete range without mode hops. This allows wavelength-dependent transmission, insertion loss, isolation, crosstalk, and spectral response measurements to be performed without discontinuities caused by sudden changes in laser mode.
The wide tuning range supports CWDM filters, multiplexers, demultiplexers, couplers, splitters, circulators, isolators, optical switches, receivers, waveguides, and other compatible devices.
The Option 132 provides a single high-power output port. Maximum output power is documented at +9 dBm peak under typical conditions.
Continuous optical output during tuning is specified at +7 dBm from 1290 nm to 1370 nm, +3 dBm from 1270 nm to 1375 nm, and 0 dBm across the complete 1260 nm to 1375 nm wavelength range.
Output power depends on wavelength, operating mode, connector interface, fiber condition, source settings, and the optical reference plane. A calibrated optical power meter should be used when the exact level delivered to a device under test must be recorded.
The wavelength-setting resolution is 0.1 pm, equivalent to approximately 17.7 MHz at 1300 nm. This fine resolution supports detailed measurements of narrow optical features and precise positioning on a required test wavelength.
Absolute wavelength accuracy is specified at ±10 pm, with typical performance of ±2.5 pm during stepped operation. Relative wavelength accuracy is specified at ±5 pm, with typical performance of ±2 pm.
Wavelength repeatability is specified at ±0.8 pm, with a typical value of ±0.5 pm. Typical wavelength stability over 24 hours at constant temperature is ±1 pm.
The 81600B Tunable Laser Source Family incorporates a real-time wavelength meter. The internal wavelength measurement system supports accurate source control without requiring an external wavelength meter for routine operation.
The specified absolute wavelength accuracy applies for one month and within a ±4.4 K temperature range after automatic wavelength zeroing. Periodic wavelength zeroing and calibration help maintain performance.
The recommended recalibration interval is two years. Calibration requirements may vary according to the measurement procedure, quality system, instrument history, and required uncertainty.
The Option 132 supports optical sweep speeds up to 80 nm/s. Specified wavelength performance is available during continuous, mode-hop-free sweeping under the documented operating conditions.
For constant-power continuous sweeps, the documented range is up to 50 nm. A representative specified condition is 1300 nm to 1350 nm at +3 dBm output.
Fast wavelength sweeping supports automated stimulus-response testing of optical filters and other wavelength-selective components. When combined with synchronized optical power meters, the source can generate detailed transmission curves efficiently.
Typical power repeatability is ±0.003 dB. Short-term power stability is specified at ±0.01 dB over one hour from 1260 nm to 1350 nm, with typical ±0.01 dB performance from 1350 nm to 1375 nm.
Typical 24-hour output stability is ±0.03 dB. Power linearity is specified at ±0.1 dB from 1260 nm to 1350 nm, with typical ±0.1 dB performance from 1350 nm to 1375 nm.
Power flatness versus wavelength is specified at ±0.2 dB, with typical ±0.1 dB performance from 1260 nm to 1350 nm and typical ±0.2 dB performance from 1350 nm to 1375 nm.
During continuous wavelength sweeps, typical dynamic power reproducibility is ±0.005 dB at 5 nm/s, ±0.01 dB at 40 nm/s, and ±0.015 dB at 80 nm/s.
Typical dynamic relative power flatness is ±0.01 dB at 5 nm/s, ±0.015 dB at 40 nm/s, and ±0.03 dB at 80 nm/s.
These specifications support rapid wavelength-resolved measurements where both tuning accuracy and optical power consistency are important.
The typical laser linewidth is 100 kHz when coherence control is disabled. The documented side-mode suppression ratio is typically 40 dB from 1270 nm to 1375 nm.
The signal-to-source spontaneous emission ratio is 45 dB/nm from 1290 nm to 1370 nm, with a typical value of 55 dB per 0.1 nm across the same region. The documented ratio is 40 dB/nm from 1270 nm to 1375 nm and typically 35 dB/nm across the complete 1260 nm to 1375 nm range.
Typical relative intensity noise is -145 dB/Hz from 1270 nm to 1375 nm under the documented maximum-output conditions.
Coherence control broadens the effective laser linewidth to greater than 50 MHz from 1270 nm to 1350 nm at flat output power. This helps reduce interference caused by reflections within fiber patch cords, connectors, and the device under test.
For measurements using 2 m patch cords and connectors with 14 dB return loss, coherence control provides typical power stability better than ±0.025 dB over one minute by reducing coherent interference effects.
Coherence control is useful when testing reflective optical components or systems where parasitic interference can introduce ripple and measurement instability.
The 81600B Option 132 uses polarization-maintaining Panda fiber. The output polarization is aligned in the slow axis, with the transverse-electric mode oriented in line with the connector key.
The typical polarization extinction ratio is 16 dB for the Option 132 configuration. A controlled output polarization helps maintain consistent measurement conditions when testing integrated optical devices, waveguides, modulators, and polarization-sensitive components.
The optical connector option must be confirmed on the individual module. Option 071 provides a straight physical-contact PMF output, while Option 072 provides an angled physical-contact PMF output.
Internal digital modulation provides a 50% duty cycle over frequencies from 200 Hz to 300 kHz. A TTL reference signal is available from the modulation output.
External digital modulation supports frequencies from 200 Hz to 1 MHz with a duty cycle greater than 45% and a fall time below 300 ns. The modulation input uses a TTL signal.
External analog modulation supports 15% modulation depth across frequencies from 5 kHz to 20 MHz. The analog modulation input requires a 5 V peak-to-peak signal.
The tunable laser supports external wavelength locking with a documented range greater than ±70 pm at 10 Hz and greater than ±7 pm at 100 Hz.
The wavelength-locking input accepts a ±5 V control signal. This function supports compatible feedback systems and experiments requiring external control of the optical wavelength.
| Brand | Agilent Technologies |
| Model | 81600B |
| Installed Option | 132 |
| Product Category | High-Power Tunable Laser Source Module |
| Optical Band | O-band |
| Wavelength Range | 1260 nm to 1375 nm |
| Maximum Sweep Speed | 80 nm/s |
| Maximum Peak Output | +9 dBm typical |
| Output Configuration | Single high-power output |
| Compatible Mainframe | Agilent 8164B Lightwave Measurement System |
| Standalone Operation | Not supported |
| Primary Application | High-accuracy O-band wavelength-resolved optical testing |
| Specification | Details |
| Wavelength Range | 1260 nm to 1375 nm |
| Wavelength Resolution | 0.1 pm, approximately 17.7 MHz at 1300 nm |
| Mode-Hop-Free Tunability | Complete 1260 nm to 1375 nm range |
| Maximum Sweep Speed | 80 nm/s |
| Absolute Wavelength Accuracy | ±10 pm, typically ±2.5 pm in stepped operation |
| Relative Wavelength Accuracy | ±5 pm, typically ±2 pm in stepped operation |
| Wavelength Repeatability | ±0.8 pm, typically ±0.5 pm |
| Typical 24-Hour Wavelength Stability | ±1 pm at constant temperature |
| Typical Linewidth | 100 kHz with coherence control disabled |
| Effective Linewidth with Coherence Control | Greater than 50 MHz from 1270 nm to 1350 nm at flat output power |
| Wavelength Region | Documented Continuous Output During Tuning |
| Peak Output | +9 dBm typical |
| 1290 nm to 1370 nm | +7 dBm |
| 1270 nm to 1375 nm | +3 dBm |
| 1260 nm to 1375 nm | 0 dBm |
| Specification | Details |
| Typical Power Repeatability | ±0.003 dB |
| One-Hour Power Stability | ±0.01 dB from 1260 nm to 1350 nm |
| Typical 24-Hour Power Stability | ±0.03 dB |
| Power Linearity | ±0.1 dB from 1260 nm to 1350 nm |
| Power Flatness versus Wavelength | ±0.2 dB, typically ±0.1 dB from 1260 nm to 1350 nm |
| Typical Side-Mode Suppression Ratio | 40 dB from 1270 nm to 1375 nm |
| Typical Relative Intensity Noise | -145 dB/Hz from 1270 nm to 1375 nm |
| Typical Output Isolation | 50 dB |
| Option | Configuration |
| 071 | Polarization-maintaining fiber with straight physical-contact output connector |
| 072 | Polarization-maintaining fiber with angled physical-contact output connector |
| Fiber Type | Panda polarization-maintaining fiber |
| Polarization Orientation | TE mode in the slow axis, aligned with the connector key |
| Typical Polarization Extinction Ratio | 16 dB |
| Connector Interface Requirement | One compatible Agilent 81000xI Series connector interface |
| Specification | Details |
| Operating Temperature | 10 °C to 35 °C |
| Storage Temperature | -40 °C to 70 °C |
| Operating Humidity | Less than 80% relative humidity, non-condensing |
| Warm-Up Time | One hour for specified performance; basic operation is available after startup |
| Recommended Recalibration Interval | Two years |
The Agilent 81600B Option 132 must be installed in the bottom slot of an Agilent 8164B Lightwave Measurement System. It is not intended for standalone operation or installation in an unsupported mainframe position.
One compatible Agilent 81000xI Series connector interface is required. The connector interface must match the installed straight-contact or angled-contact polarization-maintaining output option.
The module, mainframe, and connector interface should be inspected before installation. The module should be seated securely and recognized by the mainframe before its optical output is enabled.
The Agilent 81600B Option 132 receives comprehensive functional and performance testing before shipment. Evaluation may include recognition in a compatible Agilent 8164B mainframe, startup, wavelength tuning, output enable and disable operation, wavelength zeroing, modulation functions, and coherence-control operation.
Optical testing may include wavelength-range verification, output-power measurement, wavelength accuracy, wavelength repeatability, sweep performance, power stability, side-mode suppression, and operation of the polarization-maintaining optical output.
The module enclosure, mainframe connector, optical interface, PM fiber output, modulation connections, identification label, option markings, and laser-safety labels may be inspected for contamination, damage, corrosion, or excessive wear.
The exact testing scope depends on the installed connector option, compatible 8164B mainframe, 81000xI connector interface, wavelength meter, optical spectrum analyzer, optical power meter, PM reference cable, and requested test points.
When technically applicable and selected, the Agilent 81600B Option 132 can be calibrated or performance-verified before shipment. Evaluation may include wavelength accuracy, wavelength repeatability, tuning range, sweep rate, output power, power flatness, stability, linewidth, side-mode suppression, and modulation response.
Calibration documentation should identify the module model and serial number, Option 132 configuration, connector option, host mainframe, connector interface, wavelength points, output levels, sweep settings, warm-up time, reference equipment, recorded results, and applicable measurement uncertainty.
Buyers requiring formal calibration should specify the wavelength points, output-power levels, sweep modes, modulation tests, spectral measurements, certificate format, recorded results, and required measurement uncertainty before purchase.
Buyers should confirm the complete option configuration, including the required Option 132 wavelength range and either connector Option 071 or Option 072. The connector option determines whether the PMF output uses a straight or angled physical-contact interface.
The product listing should identify whether the Agilent 8164B mainframe, compatible 81000xI connector interface, PM patch cord, modulation cables, software, manuals, test records, or calibration documentation are included.
Only the Agilent 81600B Option 132 tunable laser module and accessories specifically identified in the product listing should be considered included.
AssetRelay supplies professional equipment and product solutions for fiber optic, telecommunications, optical testing, photonics, laboratory, production, inspection, electronic testing, RF/microwave, and technical research applications. The Agilent 81600B Option 132 provides precise O-band wavelength control for optical component manufacturers, CWDM developers, telecommunications laboratories, production facilities, system integrators, universities, and research organizations.
Buyers should review the Option 132 wavelength range, high-power output, connector option, PM fiber interface, wavelength accuracy, sweep performance, modulation functions, coherence control, compatible mainframe requirements, calibration status, functional test results, and included accessories before purchase.
Please sign in first.
Sign in